Published:
2020, 2020 Smart City Symposium Prague, New York, IEEE Press), p. 1-6), ISBN 978-1-7281-6821-0
Annotation:
The article describes experience received from one-year period of the pilot project of the air quality sensor network operation. The sensor network consists of 13 units deployed in city Litomerice. The unit - AirTracker was developed in UBTI CTU in Prague with motivation of price reduction allowing mass deployment of the network. Architecture of units and sensor network is described in the article. During the entire one-year pilot operation following values were measured: concentration of dust particles and VOC in the air and level of acoustic noise. The weather station was used to identify the characteristics of air pollution diffusion. The analysis of all data is described there along with the expectation of public authorities and the explanation of local conditions and constraints.